Restrictions
There are restrictions on which node inputs and outputs you can connect together. See Urban Developer node connection rules.
The Tank node is available for Urban Scenarios only.
Multiple TanksIn the current version of Urban Developer, you can connect more than one tank to a supply point; however this model type is not currently supported and may give inaccurate results. If you need to model a multiple-tank installation, the best workaround is to regard the entire installation as a single tank, and adjust initial levels, first-flush volumes etc, accordingly.
Node Dependencies
- Inflow: Tank inflow is usually from a roof node or other impervious area.There is no direct input capability for "topping-up" the tank; topup Inflow to a Tank node in an Urban Developer Scenario in Source is from a Roof node.
- Top-up: Tank top-up is controlled by a parameter in the tank property editor (see below). The top-up function takes water from
- the mains supply
- .
Node Outputs
- Demand: The tank volume extracted by a Water Use node per unit time.
Link type: Demand - Spill: The volume flowing out of the tank when the detention volume is exceeded.
Link type: Runoff (this link type is not currently implemented in the Urban Developer Plugin) - Detention outflow: The flow from the overflow pipe at the invert of the detention volume, during a flood event.Link type: Runoff (this link type is not currently implemented in the Urban Developer Plugin)
Node Properties
The tank parameters must be configured to represent the total number of dwellings in downstream Average or Behavioural Water Use nodes. For example, 4 houses with 10 m3 of tank volume each would need to be attached to a single tank node with 40 m3 total volume.
Property | Description | Units | Default Value | Recommended Range | Constraints | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Dimensions | |||||||||||
Cross-sectional area | Defines the cross-sectional or area of the tank base. | m2 | 2.5 | NA | >= 0 | ||||||
Height | Defines the total height of the tank. Includes detention and dead zone height and dead zone height. | m | 2 | NA | >= 0 | ||||||
Height of off-take invert | Defines the height of the offtake pipe on the tank; the offtake pipe supplies demands from the tank. The invert level of the offtake is the height of the lowest point of the pipe above the tank base. Once the tank is filled above the offtake invert level, the water depth in the tank will never fall below this level. Demand off-take occurs from the base of the tank just above the anaerobic or "dead" zone; a tank should therefore have a minimum "dead zone" depth of 0.1 m to allow for accumulation of sediment and other material. Water will never be drawn from the "dead zone". | m | 0.1 | [0, 2] | >= 0 | ||||||
Initial water depth | Defines the initial depth of water in the tank at the start of the model run. | m | 0.1 | [0, 1000] | >= 0 | ||||||
Overflow Configuration | |||||||||||
Detention volume depth | Defines the detention (storage) volume depth of the tank. The detention volume depth is the depth from above the overflow outlet invert to below the tank spill/top of the tank; hdet in the diagram. Detention volumes are used as buffers to decrease output flow rates in situations of high input flow. If the tank has no detention storage, set the detention volume depth equal to the overflow outlet diameter. | m | 0.1 | NA | [0, 2] | ||||||
Overflow outlet diameter | Defines the diameter of the overflow orifice, located at the base of the detention storage. | mm | 100 | [10, 320] | [1, 1000] | ||||||
Overflow outlet discharge coefficient | Discharge coefficient used in the evaluation of the orifice flow equation. | NA | 0.86 | NA | NA | ||||||
External top up | |||||||||||
Enable external top-up | If enabled, allows for the tank to be topped-up with mains water so that the tank always maintains a user-specified water level. You do not need to connect a mains water supply node to a tank node to provide inflow for top-up; when you enable external top-up, Urban Developer handles the mains connection internally. | NA | Disabled | NA | NA | ||||||
Top-up rate | Defines the rate of mains water top-up in litres per second. | L/s | 250 | NA | >= 0 | ||||||
Top-up triggered on | Defines the depth above the tank base at which the tank will start to top up. This depth must be greater than the height of the off-take. | m | 0.2 | NA | >= 0 | ||||||
Top-up triggered off | Defines the depth above the tank base at which the tank will stop automatically topping up. This depth must be greater than the Top-up triggered-on depth. | m | 0.3 | NA | > Top-up triggered on | ||||||
First Flush System | |||||||||||
Enable first flush system | If enabled, changes the tank inflow behaviour so that a user-specified volume of water will bypass the tank before inflow to the tank occurs. | NA | Disabled | NA | NA | ||||||
First Flush Volume | Specifies the volume of water the first-flush device diverts. | m3 | 0.015 | [0, 100] | >= 0 | ||||||
First Flush Outlet flow rate | Specifies the outflow rate to the selected discharge outlet. | m3/s | 0.01 | NA | >= 0 | ||||||
Discharges Connection | Specifies the tank outlet that first-flush outflow is discharged through. Detention outflow specifies that the first flush volume discharges via a connection to the detention outflow pipe. Spill specifies that the first flush volume discharges via spilling from the tank. | NA | NA | NA | NA | ||||||
Other | |||||||||||
Tank bypass | Not currently implemented in the Urban Developer Plugin. | NA | NA | NA | NA |
User Interface
The Tank node is configured via the node Feature Editor. Node properties are accessed through 4 levels:
Property | Interface | ||
---|---|---|---|
1 Tank Dimensions | 2 External topup | ||
3 First Flush behaviour | 4 Outflow Overflow configuration |
Acknowledgements
This material has been adapted from:
eWater Cooperative Research Centre (2011) Urban Developer Product Specification: Storage Tank Routing v0.4. eWater Cooperative Research Centre, Canberra. 23 June 2011.