The functionality provided by the environmental flow node in Source is designed to model existing and proposed water sharing arrangements that include environmental flow rules.

Source models the use of water by a combination of supply point and water user nodes. The environmental flow node (EFN) operates on a time-step basis generating demands for the environment. 

The EFN contains two types of environmental actions and allows modellers to construct an environmental water requirement by using combinations of these, rules can be grouped if required. The two types are:

  • Spell based - A spell can be defined as a period of time that the flow has a set of desired characteristics. The environmental flow node has been designed to deliver additional (environmental) flow i.e. flows over a specified threshold. Limits to flows may be set up elsewhere in the Source functionality. This type of action can by used to specify floods, freshes (usually associated with a recruitment event such as to trigger fish movement, water floodplain vegetation), a flow pattern or a minimum flow (usually applied to maintain minimum habitat requirements); and
  • Translucency - specifies the flow requirements in terms of some other time series, usually the release from a dam based on the inflow of the dam. Translucency can also be configured to represent minimum flows

Common concepts to both types of actions are- 

  • Season: the period of the year over which the rule should be considered (eg is this a winter flooding rule only);
  • Reference Flow: A representation of flow, often higher in the system or an earlier recorded 'natural' flow pattern, that can have various relationships configured in relation to it;
  • Start Threshold: Required expected flow for action to be triggered. The expected flow at the environmental flow node is the maximum of the Minimum Constraint at the upstream node and the Order at the downstream node.
  • End Threshold: A flow threshold below which the flow should fall to consider the action finished. An action or ordering period will end either when the end threshold is reached or the season has ended.

Scale

The Environmental Flow Node is applied at a point scale and operates on a daily time-step.

Provenance

The Environmental Flow node functionality was conceptualised in extensive consultation with the environmental water management organisations associated with the Murray Darling Basin in 2017.

Version

Source v4.3

Dependencies

The Environmental Flow Node is applied as a stand-alone node, which must be connected to a surface water system. To link environmental orders to accounts, or to prioritise actions across the system, an environmental flow manager and resource assessment system is required. 

Assumptions

    • Water requirements are not additive: Increased river flows and return flows can contribute to other actions (return flows can be re-credited as per normal accounting rules). 
    •  Actions can be co-dependent: A flow rule can be conditionally contingent on another flow rule also being met. This has to be configured through the importance and cost functions.
    • The highest priority water demand is for flow rules which have commenced but not yet completed. If a flow action has started, then the continuation this flow action has precedence over activation of a new flow rule.

Theory

The Environmental Flow Node is used to generate orders to meet in-stream environmental requirements at an individual asset. It can also be used to monitor defined event patterns. The rest of this document assumes you are intending to place orders that will supplement existing flows to create specific patterns of flow events. The desired flow patterns are defined by configuring one or more actions including start criteria, desired flow rate and frequency, as well as criteria for success of the action. 

The Environmental Flow Node (EFN) provides a way of capturing prescriptive descriptions of the patterns of water that the environment requires. These definitions of watering patterns are captured as ‘actions’ within the EFN, many combinations of actions can be prescribed for a single EFN. An action is a combination of a definition of the desired flow rate, duration, frequency and timing of beneficial flow events. The two types of actions presented in the EFN have been designed to capture the most commonly defined environmental flow requirements specified in environmental flow studies and water regulations. These two types of environmental actions allow users to construct a collective environmental water requirement by using combinations of actions. The two action types are:

  • Spell-based, which includes:
    • Baseflow: specifies a minimum flow; usually applied to maintain minimum habitat requirements
    • High Flow/Flood: specifies a flood fresh; usually associated with a recruitment event such as to trigger fish movement, water floodplain vegetation, moving sediment deposits
    • Pattern: specifies a pattern of flow; used to define multi-peak events.
  • Translucency: specifies the flow requirements in terms of some other time series, usually the release from a dam related to the natural inflow to the dam. Translucency is effectively a simplified version of the spell based action. 

Anchor
spellbasedaction
spellbasedaction
Spell Based Action

A High flow/Flood action defines a flow requirement above a set level. The parameters for defining a flood/fresh flow component are illustrated in Figure 4 and described below.

Figure 4. Illustration of parameters used to describe a High Flow / Flood action

A spell can be defined as a period of time that the flow has a set of desired characteristics.

A high flow spell is defined by the period of time the flow is above the target. In figure 4, (8) represents the target flow rate, and (2) represents the length of a spell.    

A season (1) is the period of time within a water year, that you desire spells to occur. Users can specify characteristics to determine the occurrence of spells desired to complete a successful season within a water year, including the number of spells, minimum independence interval (4) and desired successful season frequency (return interval). 

Once you have specified what characteristic you want, the next step is to specify the intervention you are going to take to achieve the desired outcomes defined above. The start threshold (7) defines the point after which an order may be used to augment the flow. The order is based on the rise (5) and fall (6) characteristics, the target flow (8) and minimum duration required (2,3). It is possible to extend the Minimum Spell Duration by way of a Boolean function. This allows variable spell duration's to be defined to represent various environmental flow requirements throughout the year.


Generate demands and orders for actions

The environmental flow node will generate demands and orders for actions. An Environmental Flow Node (EFN) can be assigned to an Environmental Flow Manager (EFM) or can operate in isolation. In case the actions are managed by an EFM, the EFN will only order actions that are flagged by the EFM as active. If no EFM is used, the EFN will activate actions depending on their desired return interval. In both cases, the EFN will try to piggy back on flows based on a user-defined flow threshold. That is, an action will still calculate the demand for that action even if the EFM has disabled the action. This is to allow for natural spells to be validated. A user can also determine if and when an action should be forced. If a flow threshold for piggy backing is not reached and an action is able to be forced, the EFN will start the action at the last possible day of the season.

Evaluate success and condition of action events

The success of an event is calculated by three user-configurable properties:

  1. Proportion of target
  2. Proportion of duration
  3. Proportion of volume

Proportion of target:
This specifies the minimum flow rate that must be achieved each timestep to consider the action succesful.
 For example, if a spell has a target flow of 50ML/d and a Proportion of target = 50%, the node must receive at least 25ML/d every timestep during an event to be a success

Proportion of duration:
This specifies the proportion of timesteps  in an event that meet the proportion of target criteria. For example, if a spell is configured with:
  • Target flow = 50ML/d
  • Proportion of target = 50%
  • Proportion of duration = 70%
  • minimum spell duration = 10 days
For this spell to be successful, the node must have received 25ML for at least 7 days.

Proportion of volume:
This specifies the minimum total volume that the node must receive over the event. An event is successful if the cumulative volume received over the event is greater than the cumulative target volume x Proportion of Volume. For example, if a spell is configured with:
  • Target flow = 50ML/d 
  • Proportion of volume = 70%
  • Minimum spell duration = 10 days
For this spell to be successful, the node must receive 50*10*0.7 = 350ML.

All three of these must be satisfied for the event to be considered a success

If the end spell if it will fail option is turned on, a spell is stopped if success is determined to no longer be possible. Since this is calculated during spell execution, only proportion of target and proportion of duration criteria are used.
This is done by keeping a counter of the number of timesteps that were successful based on the target flow criteria. If this counter is greater than the minimum spell duration x (1- Proportion of duration) (i.e. the maximum number of failure timesteps) then the spell is stopped.

The success of an action's season is configurable to be equal to or less than the required number of spells in a season.
Success will be calculated as the model runs and days since last success will be recorded for use in the calculation of condition.

The user can specify a condition function, but by default, the condition is calculated as

EXP(-time since last successful / average return interval).

Antecedent Condition


with Average Recurrence Interval being calculated from the Desired Frequency:

For example, desired frequency is 2 in 3 years, the Average Return Interval is 365 / (2/3) = 547.5 (days).

The Antecedent Condition equation returns a value between 0 and 1 (0 is poor condition and 1 is good condition). The user-defined function is not restricted to return a value between 0 and 1, however, it is strongly recommended to consider the implications before changing the output range.

Antecedent Condition is used by the EFM to determine the priority of an action. 


Anchor
riseandfall
riseandfall
Rise and Fall Calculations:

There are 3 methods provided to calculate the rise and fall duration and demand volumes:

  • Days
  • Rate
  • Percentage

Each method simply calculates a duration and a demand based on two flow values. In the case of rise, these flow values are the expected flow and the target volume on the first timestep the spell was in the Rise Phase state. The expected flow will be either minimum constraint or downstream order depending on what triggered the spell (i.e if triggered by an upstream constraint, the expected flow will be the upstream constraint). In the case of fall, the two flow values are the Target Flow and the Fall Target.

Info

Note: Rise and fall will only be used for 'managed' spells. i.e. a spell that the EFN will place an order for. This means for natural spells, the rise and fall duration is effectively zero. Also note that it is possible for a managed spell to be successful by downstream orders or upstream constraints. If it is, the EFN will still wait for the rise and fall duration before a new spell is triggered. This means depending on the type of spell, some recorders will be updated slightly differently (e.g. Number of successful spell in a season)


Days

The Days method simply calculates a linear increase (or decrease for fall) between two flows

Rise:

Duration =  day value or zero if the expected flow >= target flow.

let increment = (target flow - expected flow) / days

Environmental Flow Requirement = Min(target flow, expected flow +  increment * days in rise phase)


Fall :

Duration = day value or zero if the target flow <= Fall Target

let decrement = (target flow -Fall Target) / days

Environmental Flow Requirement = Min(target flow, expected flow  - decrement * days in fall phase)


Rate

Rate method increments at a constant rate regardless of the initial expected flow.  

Rise:

Duration =  (target flow - expected flow)/ Rise Rate or zero if the expected flow >= target flow.

Environmental Flow Requirement = Min(target flow, expected flow +  Rise Rate * days in rise phase)


Fall :

Duration =  (target flow - expected flow)/ Fall Rate or zero if the target flow <= Fall Target

Environmental Flow Requirement = Min(target flow, expected flow -  Fall Rate * days in fall phase)

 

Percentage

The percentage method increases or decreases the demand by a constant percentage every day.

Rise:

Duration =  day value or zero if the expected flow >= target flow.

Environmental Flow Requirement = expected flow * (1 + increment) on the first day

                 last timesteps demand * (1 + increment) on the following days.

Fall :

Duration = day value or zero if the target flow <= Fall Target

Demand = expected flow * (1 - decrement) on the first day

                 last timesteps demand * (1 - decrement) on the following days.


...