Restrictions
There are restrictions on which node inputs and outputs you can connect together. See Urban Developer node connection rules.
Node Inputs
Node Input | Notes |
---|---|
Mains supply | Connect to a mains supply node (if available) |
Tank supply | Connect to a tank node (if available) |
Alternative supply 1 | Connect to an Alternative supply node (if available) |
Alternative supply 2 | Connect to an Alternative supply node (if available) |
Node Outputs
Node Output | Notes |
---|---|
Blackwater | Connect to a blackwater stream (if necessary) |
Greywater | Connect to a greywater stream (if necessary) |
Irrigation/Other | Connect to any other end-use stream. For example, you can track your garden irrigation through this end-use, and link it back to a pervious area node in your model to capture the effects of run-off of irrigating your pervious area. |
Node Properties
Node Property | Notes |
---|---|
Diurnal pattern | This allows you to set the diurnal water usage pattern. The diurnal pattern is currently not editable in the Urban Developer Plugin. |
Indoor average demand | The average indoor demand each month in litres/day/household. This is used to characterise the seasonal variation in water usage. |
Outdoor average demand | The average outdoor demand each month in litres/day/household. This is used to characterise the seasonal variation in water usage. |
Total Demand Proportion (indoor/outdoor) | For each end use, enter the percentage of total indoor or outdoor demand. The Total Demand Proportion can also be used to capture the proposed effects of demand management strategies. Percentages for indoor end-uses must sum to 100, and percentages for outdoor end-uses must summ to 100. |
Supply Priorities (indoor/outdoor) | For each indoor/outdoor source, enter an order of preference for supply; eg for the end use "Toilet":
The option Don't Supply specifies that mains water, rainwater, etc will not supply that particular end use. |
Discharge breakdown (indoor/outdoor) | For each end-use, specify the percentage of water discharged as blackwater, greywater, or other wastewater. The percentages must sum to 100%. |
Configuration Interface
Average Water Use nodes currently use Scenario Input Sets (Edit»Scenario Input Sets) for configuration. Example configuration format is shown below
Nodes.Average Water Use 1.Indoor.Hot Water.Demand Management Reduction=39%
Nodes.Average Water Use 1.Indoor.Hot Water.Discharge Breakdown.Blackwater=100%
Nodes.Average Water Use 1.Indoor.Hot Water.Discharge Breakdown.Greywater=0%
Nodes.Average Water Use 1.Indoor.Hot Water.Discharge Breakdown.Irrigation=0%
Nodes.Average Water Use 1.Indoor.Hot Water.Supply Priorities.Alternate Supply 1=Don't Supply
Nodes.Average Water Use 1.Indoor.Hot Water.Supply Priorities.Alternate Supply 2=Don't Supply
Nodes.Average Water Use 1.Indoor.Hot Water.Supply Priorities.Mains=1
Nodes.Average Water Use 1.Indoor.Hot Water.Supply Priorities.Rainwater Tank=Don't Supply
Nodes.Average Water Use 1.Indoor.Hot Water.Total Demand Proportion=39%
Nodes.Average Water Use 1.Indoor.Laundry.Demand Management Reduction=23%
Nodes.Average Water Use 1.Indoor.Laundry.Discharge Breakdown.Blackwater=100%
Nodes.Average Water Use 1.Indoor.Laundry.Discharge Breakdown.Greywater=0%
Nodes.Average Water Use 1.Indoor.Laundry.Discharge Breakdown.Irrigation=0%
Nodes.Average Water Use 1.Indoor.Laundry.Supply Priorities.Alternate Supply 1=Don't Supply
Nodes.Average Water Use 1.Indoor.Laundry.Supply Priorities.Alternate Supply 2=Don't Supply
Nodes.Average Water Use 1.Indoor.Laundry.Supply Priorities.Mains=1
Nodes.Average Water Use 1.Indoor.Laundry.Supply Priorities.Rainwater Tank=Don't Supply
Nodes.Average Water Use 1.Indoor.Laundry.Total Demand Proportion=23%
Nodes.Average Water Use 1.Indoor.Other.Demand Management Reduction=13%
Nodes.Average Water Use 1.Indoor.Other.Discharge Breakdown.Blackwater=100%
Nodes.Average Water Use 1.Indoor.Other.Discharge Breakdown.Greywater=0%
Nodes.Average Water Use 1.Indoor.Other.Discharge Breakdown.Irrigation=0%
Nodes.Average Water Use 1.Indoor.Other.Supply Priorities.Alternate Supply 1=Don't Supply
Nodes.Average Water Use 1.Indoor.Other.Supply Priorities.Alternate Supply 2=Don't Supply
Nodes.Average Water Use 1.Indoor.Other.Supply Priorities.Mains=1
Nodes.Average Water Use 1.Indoor.Other.Supply Priorities.Rainwater Tank=Don't Supply
Nodes.Average Water Use 1.Indoor.Other.Total Demand Proportion=13%
Nodes.Average Water Use 1.Indoor.Toilet.Demand Management Reduction=25%
Nodes.Average Water Use 1.Indoor.Toilet.Discharge Breakdown.Blackwater=100%
Nodes.Average Water Use 1.Indoor.Toilet.Discharge Breakdown.Greywater=0%
Nodes.Average Water Use 1.Indoor.Toilet.Discharge Breakdown.Irrigation=0%
Nodes.Average Water Use 1.Indoor.Toilet.Supply Priorities.Alternate Supply 1=Don't Supply
Nodes.Average Water Use 1.Indoor.Toilet.Supply Priorities.Alternate Supply 2=Don't Supply
Nodes.Average Water Use 1.Indoor.Toilet.Supply Priorities.Mains=1
Nodes.Average Water Use 1.Indoor.Toilet.Supply Priorities.Rainwater Tank=Don't Supply
Nodes.Average Water Use 1.Indoor.Toilet.Total Demand Proportion=25%
Nodes.Average Water Use 1.Indoor Average Demand=[
0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.
Nodes.Average Water Use 1.Latitude=0
Nodes.Average Water Use 1.Longitude=0
45 0.45 0.45 0.45 0.45]
Nodes.Average Water Use 1.Outdoor.Garden.Demand Management Reduction=100%
Nodes.Average Water Use 1.Outdoor.Garden.Discharge Breakdown.Blackwater=0%
Nodes.Average Water Use 1.Outdoor.Garden.Discharge Breakdown.Greywater=0%
Nodes.Average Water Use 1.Outdoor.Garden.Discharge Breakdown.Irrigation=100%
Nodes.Average Water Use 1.Outdoor.Garden.Supply Priorities.Alternate Supply 1=Don't Supply
Nodes.Average Water Use 1.Outdoor.Garden.Supply Priorities.Alternate Supply 2=Don't Supply
Nodes.Average Water Use 1.Outdoor.Garden.Supply Priorities.Mains=1
Nodes.Average Water Use 1.Outdoor.Garden.Supply Priorities.Rainwater Tank=Don't Supply
Nodes.Average Water Use 1.Outdoor.Garden.Total Demand Proportion=100%
Nodes.Average Water Use 1.Outdoor.Other.Demand Management Reduction=13%
Nodes.Average Water Use 1.Outdoor.Other.Discharge Breakdown.Blackwater=100%
Nodes.Average Water Use 1.Outdoor.Other.Discharge Breakdown.Greywater=0%
Nodes.Average Water Use 1.Outdoor.Other.Discharge Breakdown.Irrigation=0%
Nodes.Average Water Use 1.Outdoor.Other.Supply Priorities.Alternate Supply 1=Don't Supply
Nodes.Average Water Use 1.Outdoor.Other.Supply Priorities.Alternate Supply 2=Don't Supply
Nodes.Average Water Use 1.Outdoor.Other.Supply Priorities.Mains=1
Nodes.Average Water Use 1.Outdoor.Other.Supply Priorities.Rainwater Tank=Don't Supply
Nodes.Average Water Use 1.Outdoor.Other.Total Demand Proportion=13%
Nodes.Average Water Use 1.Outdoor Average Demand=[0.24213 0.21374 0.14635 0.11088 0.06253 0.05918 0.06579 0.11799 0.18973 0.25765 0.24772 0.26243]
Nodes.Average Water Use 1.Deactivated=FALSE
Nodes.Average Water Use 1.Elevation=0 m
Nodes.Average Water Use 1.Latitude=0
Nodes.Average Water Use 1.Longitude=0