When using linear routing (= 1), the units of the storage constant k are in seconds. For models using daily time-steps, the recommended starting value is 86400 (the number of seconds in one day). When using non-linear routing (m ≠ 1), the recommended starting value should be calculated as follows:

Equation 43

For example, if the reach length is 1000 metres, the time-step is one day, and = 0.8:

Equation 54