- The flux based on flow up to the high flow threshold is shared according to fixed ratio. This volume is:
Data
Input data
Details on data requirements are provided in the Source User Guide.
Parameters or settings
Input parameters and settings for ownership specified at the level of the link (as distinct from input parameters and settings at the ownership system level which apply to all links, and nodes, in the ownership system) are summarised in Table 3.
Table 3. Link ownership parameters
Parameter name | Parameter description | Unit type | No. of values | Allowable values & validation rules | Default value(s) |
---|---|---|---|---|---|
Ownership system | Name of the ownership system the link sits within. | n/a | 1 | Read only | Link's ownership system |
Configure time series flux per owner | Indicates whether each owner's time series flux is to be configured on the link (if so, overrides ownership system sharing method) | n/a | 1 | Yes or no | No |
Murray-style losses: High flow threshold | For Hurray-style high flow losses: Threshold above which high flow losses occur | Volume/time | multiple | Real ≥ 0 | Owner in link's ownership system |
Owner | Name of the owner the row's share parameters apply to | % | One per owner | Read only | Value for link's ownership system |
Dead storage % | Owner's percentage of dead storage in the link | % | One per owner | Read only | Value for link's ownership system |
Time series flux % | Owner's percentage of link time series fluxes that are shared according to fixed ratio | % | One per owner | Read only | Value for link's ownership system |
Other lateral flux % | Owner's percentage of other link lateral fluxes that are shared according to fixed ratio | % | One per owner | Read only | Value for link's ownership system |
Initial flow or live storage % | Owner's percentage of initial flow or live storage in the link | % | One per owner | Rea, 0 - 100 Total of all owners = 100%y | Equal value per owner |
Output data
Output potentially available is summarised in Table 4.
Table 4. Link Ownership Output Variables
Model element | Parameter | Units | Freq. | Display format |
---|---|---|---|---|
Division + owner | Upstream flow | Volume/time | Time-step | Displayed as: |
Upstream flow volume | Volume | |||
Downstream flow | Volume/time | |||
Downstream flow volume | Volume | |||
Storage volume | Volume | |||
Live storage volume | ||||
Dead storage volume | ||||
Lateral flow volume | ||||
Borrow balance | Volume | See Borrow and Payback | ||
Net borrow | ||||
Link + owner | Same as above. Link upstream inflow = first division's upstream inflow, link downstream outflow = last division's downstream outflow. Storage is total for all link divisions. |