  1. If the division is transitioning from dead to live (i.e. Statet-1 = Dead) and Storage(t - 1) < StoragedsMAX, Storage(t - 1), and the fixed lateral flux for each owner, Lossfixed(o), are adjusted as described in the Division transitioning from dead to live section under Ownership adjustments (equations (47), (48), (49) and (50) above).  The steps are:
    1. Adjust each owner’s fixed lateral flux to include the volume to fill dead storage

      Equation 88 Image Added
    2. Set the apparent storage for last time step to the maximum dead storage.

      Equation 89Image Added
    3. Set the apparent storage for each owner at the last time step to their share of the maximum dead storage.

      Equation 90Image Added
  2. Calculate the total ‘live’ storage for reporting (and use in further calculations), where Storagelive = Storage(t) - StoragedsMAX as per equation (20).
  3. Calculate trial storage volumes for each owner (that assume no high flow loss):
    1. If

    there is a high flow loss (LossHF > 0):Calculate each owner’s share of each proportional lateral flux for reporting using equation (20)
    1. Muskingum  x = 1, outflow and storage are not interdependent, so the proportional routing model can be applied directly:  

      Equation 91Image Added
    2. Otherwise outflow and storage interact, so a more complex method is needed:
      1. Adjust owner fixed lateral fluxes to ensure no owner has a negative outflow:

        1. To determine the ratio r, use equation (21)

          Equation 92Image Added

          (Note that Storagelive = Storage(t) - StoragedsMAX)

        2. Adjust owner fixed lateral fluxes to ensure no owner has a negative outflow. This involves finding the maximum fixed loss that each owner can sustain with non-negative outflow and the resultant surplus/deficit using equations (51), (52) and (53). 

        3. Pass owner surpluses and deficits to the Borrow method (Refer to Borrow and Payback - SRG for more information). This will return how much owners borrowed or lent (OwnerBorrowed(o), OwnerLent(o)).

        4. For each owner: Add amount lent and subtract amount borrowed from the fixed loss:

      2. Use the proportional routing model equation (37) to determine trial volumes for each owner (assuming no high flow losses at this stage): 
  4. If there is a high flow loss (LossHF > 0):
    1. If Muskingum x ≠ 1 high flow losses will impact storage volumes. The approach described  in the section on High flow loss formula (Murray-style), under Live division model, assumptions and equations above, is used to determine the final storage volume for each owner.

    2. Calculate owner shares of the high flow loss using equation (26): 
  5. Calculate each owner’s share of each proportional lateral flux for reporting using equation (20), after rearranging so the term Lossprop is on the right hand side (i.e. by rearranging to match the form of equation (13)):
    1. If the time series flux is configured to be shared proportionally 
    2. If other lateral fluxes are configured to be shared proportionally:


Details on data requirements are provided in the Source User Guide.

...