Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The riversystem.commandline.exe provides a mechanism to run existing projects without the Source interface. It is possible to modify or change the behaviour of the project from the command line, by changing the values of global expressions. Results can be returned for recorded items or global expressions within the project.

 riversystem.commandline.exe is included with Source.

...

 
Anchor
CommandLineOptions
CommandLineOptions
Table 1. Command Line Runner (options)
 
-r "someResult" -r "someOtherResult"-a "net.pipe://localhost/PipeReverse" or "net.tcp://localhost:8523/eWater/Services/RiverSystemService

Display option commands

Function

Example

-a, --address

Address for server to create, or client to connect.-a "net.pipe://localhost/PipeReverse" or "net.tcp://localhost:8523/eWater/Services/RiverSystemService"
-b, -baseSIUnitsIgnore units set within project and output base SI units --baseSIUnits
-c, --recordingFile to load state from when in when in client mode or file to save state in when in server mode.-c "c:\StateFiles\state.txt"
-d, --directoryDirectory in which to look for projects in.-d "c:\ProjectFiles"
-e, --timeoutOperation timeout for WCF service in seconds.-e 2000
-f, --settingFileFile to merge command-line settings from.-f "settings.txt"
-g, --getProjectDescriptionWrite the xml description of the project to the specified file name. If the -g parameter exists use the xpath to query and return a subset of the project description. The string arguement is the file name to the write the project details into. If used without the -x arguement all the project details are written-g "projectdescription.xml"
   
   
   
   
   
   
   

-p, --project

Path to project, or project name on server followed by these optional parameters: scenario within that project, start and end times, name of data input set

-p "projectName.rsproj" or -p "c:\somePath\projectName.rsproj;someScenarioName;1/1/2011;31/12/2011;dry"

-m, --mode

Application mode Client/Server/InProcess.

-m Client or -m Server

-d, --directory

Directory in which to look for projects.

-d "c:\ProjectFiles"

-o, --output

File to save output into. The extension selects the output format based on the standard TIME I/O formats. A directory of the name specifed will be created if the format only supports a single time series.

-o "output.res.csv" for CSV or -o "output.nc" for NetCDF etc.

-r, --results

Which results to return. This can appear multiple times.

Info
iconfalse
Note: By default, all recorded results are saved into the specified output file. When this options is used, it only allows you to reduce the number of results saved out. Requested results must be set to record in the project file. To specify the output file name, save the result to a file with a .res.csv extension. Use the column name for the time series.
-l, --loadPluginFile load as a plugin. Plugins saved in the project file are always loaded by default; this option allows a plugin that the project has not been saved with to be loaded for this run only using default options.-l "plugin.dll"
-m, --modeApplication mode Client/Server/InProcess.-m Client or -m Server
-o, --outputFile to save output into. The extension selects the output format based on the standard TIME I/O formats. A directory of the name specified will be created if the format only supports a single time series.-o "output.res.csv" for CSV or -o "output.nc" for NetCDF etc.

-p, --project

Path to project, or project name on server and optional scenario within that project, DateTime values to override the default start and end times of the loaded scenario and data source input set to run.

-p "projectName.rsproj" or -p "c:\somePath\projectName.rsproj;someScena
rioName" or -p "c:\somePath\projectName.rsproj;;1/1/2011;31/12/2011" or -p "c:\s
omePath\projectName.rsproj;;;;inputSetName"

-r, --results

Which results to return. This can appear multiple times.

Info
iconfalse
Note: By default, all recorded results are saved into the specified output file. When this options is used, it only allows you to reduce the number of results saved out. Requested results must be set to record in the project file. To specify the output file name, save the result to a file with a .res.csv extension. Use the column name for the time series.

-r "someResult" -r "someOtherResult"

-s, --stepNumber of time-steps to run.--step 1
-t, --resetReset the loaded project.--reset
-u, --currentReturn only the current time-step's value for the specified results--current

-v, --value

Set value of meta-parameter or internal setting.

-v "$metaparam=25", or -v "$anotherMetaParam=2.3"

-s, --step

Number of time-steps to run.

--step 1

-t, --reset

Reset the loaded project.

 

-e, --timeout

Operation timeout for WCF service in seconds.

-e 2000

-b, -baseSIUnits

Ignore units set within project and output base SI units

 

"

-x, --xPathProjectDescription

An optional xpath used to query and return a subset of the project description. The string arguement can be empty in which case the full descripiton is returned. Data is written to file name specified with the -g arguement or a default file (ProjectDescription.xml).

-x "" or -x "//entity@name='Node'"

PEST calibration using the command line

PEST (Parameter ESTimation and uncertainty analysis) allows analysis of complex environmental models, and can be used in Source for calibration of catchments. You can use the command line to do calibration and uncertainty in a catchments model. The steps to do the calibration are as follows:

  • Starting with a Source Catchment project file, use the new calibration tool to set up ‘global expressions’ for the parameters of the rainfall runoff models. When defining the metaparameters in the Calibration Wizard, the list of Existing Metaparameters will be used in the parameter file for invoking riversystem.commandline;
  • Turn on any recorders for the hydrological quantities that will be used in the objective function. In step 4 of the Calibration Wizard, choose Manual optimisation and enable Create global expressions for use from an external tool;
  • Save the project;
  • Set up the Riversystem.Commandline input file;
  • Setup the PEST input and template files;
  • Prepare a batch file to invoke the commandline and pre-processors; and
  • Run PEST.

Once the Calibration wizard has been set up, start the command line server (riversystem.commandline -p projectname.rsproj -m server) and then PEST (pest pestcontrolfile.pst).

Batch running using the command line

Insert excerpt
SC:Batch running using the command line
SC:Batch running using the command line
nopaneltrue