Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

SymbolDescriptionUnits
dtModel time-steptime
Deficit(o)Owner’s deficit to be made up using borrow and payback.volume
   
   
FluxTSSequence of time series flux values for the link input by the modeller.  
FluxTS(o)Sequence of time series flux values for the link for owner o, input by the modeller. 
 Storage routing function used to determine the live storage volume in a link division. See the Link Storage Routing SRG for more information.volume
gLinear function to translate between ratios: from change in storage/total storage into change in flow/total flow.n/a
jAn owner whose current storage contributes to the high flow loss, i.e. is greater than their share of the high flow threshold.n/a
IDivision inflow volumevolume
I(o)Division inflow volume for owner ovolume
LossTotal volume of loss from the division (negative if water is gained).volume
LossfixedTotal volume of loss that is shared in a predetermined way. It is assumed to have been adjusted to reflect any shortfall in volume to meet it during the flow phase (trying to pump a division dry for example).volume
Lossfixed(o)The (volume) share of fixed loss owned by owner o.volume
LossfixedMAX(o)Maximum fixed loss that owner o has the capacity to sustain.volume
LossHFTotal high flow lossvolume
LossHF(o)High flow loss for an owner volume
LosspropTotal volume of loss that should be shared in proportion to the ownership of the water in the division. This volume is assumed to have been adjusted to reflect any shortfall that occurred in the flow phase (such as a division with non-zero area at empty trying to evaporate water from an empty division). 
Lossprop(o)The (volume) share of proportional loss owned by owner o.volume
mMass of the sample takenmass
miMass of the substance in the samplemass
MTotal mass in a specified volumemass
MiMass of substance  in a specified volumemass
noNumber of ownersn/a
Net(o)Net volume of water that owner o has in storage (in a “dead” division)volume
ODivision outflow volume, including outflowing lateral fluxesvolume
O(o)Division outflow volume for owner ovolume
oOwner of water in the divisionn/a
 Division index flow rate, which is the index flow for the current time step. See the Link Storage Routing SRG for more information.volume/time
 Owner’s share of division’s index flow rate for the current time step.volume/time
 Threshold for high flow/upper limit to regulated flow (used to determine high flow losses).volume/time
rSymbol used to simplify mass balance equations. 
Ratiods(o)Owner o’s share/ratio of the dead storage volume. This value is specified by the modeller.n/a
Ratiolive(o)Owner o’s ratio of index flow rate to total index flow rate. Used to calculate their share of active storage and proportional losses.n/a
Ratioloss(o)Owner o’s share/ratio of losses. 
RatioHFT(o)Owner o’s share/ratio of the high flow threshold. This value is specified by the modeller.n/a
RatioTS(o)Owner o’s share/ratio of time series flux. 
StorageCurrent total volume of water stored in the division.volume
Storage(o,t)The total volume of water stored in the division at time step  owned by owner o.volume
Storage(o,t-1)Total volume of water stored in the division at the previous time-step (t-1) owned by owner o. 
Storage(t)Total volume of water stored in the division at time-step t.volume
Storage(t-1)Total volume of water stored in the division at the previous time-step t-1. 
StoragedsCurrent dead storage in the division. If the division is dead, this is the total division storage, Storage(t). If the division is live this is StoragedsMAX.volume
Storageds(o)Current dead storage in the division owned by owner o. 
StoragedsMAXMaximum total dead storage in a division specified by the modeller.volume
StoragedsMAX(o)Owner o’s share of the maximum total dead storage in a division.volume
StorageexcludeTotal volume of water at current time step belonging to owners that are not contributing to the high flow loss.volume
StorageHFTDivision storage threshold that corresponds to reach high flow rate threshold qHFT, i.e. .volume