Option 1: Assumes a constant surface area at each time step, as defined by the Max dam surface area input at the farm dam UI (Equation 1)
...
Where:
At - The surface water area at time step t
C – a constant defined by the input parameter Max. Dam Surface Area
Option 2: Allows a variable surface area per time step calculated as a non-linear function of storage volume at that time step using default coefficients according to a regression relationship 1 (Equation 2):
...
Where:
Vt-1 - The surface storage volume at the previous time step. If t is 1 (i.e., the first modelled time step), the initial water volume at the farm dam is used as defined by the Initial Storage Percentage
0.0006367522 and 1.071 are default values for coefficients A and B, respectively, as defined in Equation 3
References
1 McMurray, D, 2004. Farm Dam Volume Estimations from Simple Geometric Relationships. Department of Water, Land and Biodiversity Conservation. South Australia. Report No. DWLBC 2004/48.