The Schematic Editor allows you to create and manage an operations or schematic scenario.
...
- Edit opens the selected component's feature editor where you can edit its configuration
- Rename the selected component
- Activate selected component(s) if it has previously been deactivated
- Deactivate selected component(s), see below for details.
- Multi-activate activates the selected component and either all upstream component or all downstream components (including all components in tributaries), based on your choice from the sub-menu.
- Multi-deactivate deactivates the selected component and either all upstream components or all downstream components (including all components in tributaries), based on your choice from the sub-menu.
- Add opens a sub-menu listing all nodes. Select a node from the list and it will be added at the place you clicked. This option is synonymous to dragging a node from the node palette on to the schematic. It is only visible in the contextual menu if you right click on a blank area in the Schematic Editor, rather than on a component.
- Copy the selected component(s)
- Delete removes the selected component(s) from the scenario
- Paste the selected component(s) you have previously copied
- Apply Params to All Links applies the parameters of the selected link to all links in the scenario
- Routing Type changes the type of the selected link. Choose the link routing type from the resulting sub-menu
- Line Type changes the representation of the selected link to either elbow (orthogonal) lines (Figure 2, left pane) or a straight line (Figure 2, right pane). Each line has one control point which you can adjust to route the line around obstacles. The control point for an orthogonal line can only be moved in the vertical dimension whereas the control point for a straight line has no restrictions on its movement
- Rotate rotates the orientation of the selected node(s) to the orientation chosen from the sub-menu. The default direction is 0 degrees, which corresponds to North to South. See below for more information.
Grid Settings... opens the grid settings dialog (Figure 3). Here you can choose to:Anchor GridSettings GridSettings - Toggle display of the grid using Display Grid. The default state is off but the setting is saved with your project. This is synonymous to the Display Grid button in the Schematic Editor display toolbar (Figure 65).
- Toggle whether nodes will snap to the grid when moved within Schematic Editor using Snap to Grid. Turning this setting on does not affect the alignment of existing nodes. Alignment with the grid is only enforced when you drag a node. Figure 3 compares the appearance of the Schematic Editor with the Snap to Grid control turned off (left) versus on (Grid Size is 50 pixels in centre and 100 pixels on right). The default state is off but the setting is saved with your project. This is synonymous to the Snap to Grid button in the Schematic Editor display toolbar (Figure 65).
- Change the frequency of grid lines using Set Grid Size. The default is 10 pixels but the setting is saved with your project. Figure 4 shows the appearance of the Schematic Editor with a grid size setting of 10 pixels (left), 50 pixels (centre) and 100 pixels (right). This is synonymous to entering the grid size in the Schematic Editor display toolbar Editor toolbar (Figure 65).
Figure 2. Schematic Editor options comparison
...
Figure 4. Snap to grid on/off comparison
Anchor | ||||
---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
...
toolbar (refer to Figure 5)
- You can work with links and nodes in the Schematic Editor using Enable connecting link to a different node. This button allows you to disconnect the end of a link from the node to which it is attached, and then reconnect that link to another node. You can use this feature to insert new nodes into a schematic without losing the configuration of existing links.
Straight Lines
controlstoggles the representation of links
. Source defaults to drawing links using elbow (orthogonal) lines. Click this button to change the default representation to straight lines. The left and centre schematics of Figure 2 show the difference between how a model will be represented after you press the button. Theto straight lines (eg. Figure 2, centre and left schematics) from the default of orthogonal (elbow) line (Figure 2, right schematic). The representation of any link can be controlled independently using the contextual menu in the Schematic Editor. Right-click the link and choose one of the options in the Link Type sub-menu. Each line has one control point which you can adjust to route the line around obstacles. The control point for an orthogonal line can only be moved in the vertical dimension whereas the control point for a straight line has no restrictions on its movement. The representation of any link can be controlled independently using the contextual menu in the Schematic Editor. Right-click the link and choose one of the options in the Link Type sub-menu.
Node Labels controls whether the names of nodes are shown inInfo icon false Note: At present, only the setting of the Straight Lines button is saved with your project. Any changes you make to individual links or control points are lost when you close your project. - Note/Error icons toggles the view of any notes and/or errors that are present in theSchematic Editor.
- Node Labels toggles the view of node names the Schematic Editor. Source defaults to displaying node names . The schematic in the centre of Figure 2 shows the behaviour of the Schematic Editor with the Node Labels control turned on(Figure 2, centre schematic).
- Link Labels controls whether toggles the names of links are shown view of link names in the Schematic Editor. Source defaults to displaying link names . The schematic on the right of Figure 2 shows the behaviour of the Schematic Editor with the Link Labels control turned on.Track controls whether the Schematic Editor always scrolls to show components as they are selected in the Project Hierarchy. The (Figure 2, left schematic).
- Track when enabled, the Schematic Editor window will scroll to bring into view any node or link that you select in the Project Hierarchy. You can use this feature to locate components in large models. The default state of this button is off. In this mode, Source leaves the Schematic Editor window unchanged, regardless of any selections you may make in the Project Hierarchy. If you turn Track on, the Schematic Editor window will scroll to bring into view any node or link that you select in the Project Hierarchy. You can use this feature to locate components in large models.Overview Panel controls whether the Overview Panel is shown in
- Overview Panel toggles the display of the Overview Panel in the Schematic Editor. The default state of this control is off. You can use this button to the Overview Panel to obtain a thumbnail view of your entire schematic. You You can drag the Overview Panel to any point within the Schematic Editor, but you cannot pan the Schematic Editor by dragging within the Overview Panel.
- Pan - controls movement of the drawing surface. When this button is when enabled, clicking and holding on any part of the drawing surface in the Schematic Editor moves the entire drawing surface. This is an alternative to using the scroll bars.
- Tool tips - controls the view of tool tips containing information about a component's name, elevation and type. A storage node contains additional information including its capacity, height and surface area:
Tool tips on – when selected, clicking on any node in the Schematic Editor causes a small floating window to appear which that contains additional information about that nodecomponent;
Tool tips off – when selected, the floating windows do not appear; and
Tool tips locked – when selected, clicking any node component in the Schematic Editor causes a small floating window to appear next to every nodecomponent.
- Show/hide water user and bulk licensing links - controls the view of links between the following types of nodes:
- Supply point and water user nodes; and
- Bulk licensing and gauge nodes.
Info | ||
---|---|---|
| ||
Note: At present, only the setting of the Straight Lines button is saved with your project. Any changes you make to individual links or control points are lost when you close your project. |
Figure 5. Schematic Editor options toolbar
...
- Toggle display of the grid using Display Grid. This is synonymous with Display Grid toggles display of the grid. This is synonymous with the Grid Setting dialog option option.
- Toggle Snap to Grid toggles whether nodes will snap to the grid when moved within Schematic Editor using Snap to Grid. This is synonymous with the Grid Setting dialog option.
- Change Set Grid Size changes the frequency of grid lines using Set Grid Size. The default is 10 pixels but the setting is saved with your project. Figure 4 shows the appearance of the Schematic Editor with a grid size setting of 10 pixels (left), 50 pixels (centre) and 100 pixels (right). This is synonymous with the Grid Setting dialog option.
- You can view a sample printed copy of the model displayed in the Schematic Editor using Print (in the Schematic Editor display toolbar). At present, the Print opens the Print preview dialog allowing you to save the schematic in the Schematic Editor as a pdf. The entire schematic is scaled to fit within a single A4 page in portrait mode. An An example is shown in Figure 7Figure 6;You can save a Source model in .JPEG format using
- Save as Image (in the Schematic Editor display toolbar).This command opens a standard file dialog box so that you can choose where to save the image. At present, the saves the entire schematic in the Schematic Editor as a *.jpg. The entire schematic is scaled to fit within a single A4 page in portrait mode.
- You can view the zoom and undertake various zoom actions using the zoom icons on the right side of the toolbar:
- Current zoom
displays - displays the value of the zoom that is currently used in the Schematic Editor. This value has a range of of
10 – 200%- 10 – 200%;
- Zoom in
allows - allows you to zoom into a particular part of the mode (or Ctrl and + on your keyboard's number pad or Ctrl and scroll up with your mouse scroll wheel). Similarly, Zoom out allows you to zoom out (or Ctrl and - on your keyboard's number pad or Ctrl and scroll down with your mouse scroll wheel). Both actions are performed in increments of approximately 10%; and
- The last two icons ensure that the entire model fits into the Schematic Editor screen. As its name suggests, Fit to width
ensures - ensures that entire model is visible horizontally in the window. Clicking Fit to window
will - will display the entire model in the window.
Figure
...
5. Schematic Editor
...
toolbar
Figure
...
6. Schematic editor, Print Preview
Anchor | ||||
---|---|---|---|---|
|
...
- Click on a node to select it. A green circle handle will appear, you can drag the handle to rotate the node (Figure 87, left node).
- Right click a node or a selection of nodes and choose Rotate from the contextual menu (Figure 1). Then choose either the default direction or one of the four compass directions from the sub-menu (Figure 87, right nodes). You can set the default rotation in Edit » Scenario Options, then select Default Node Rotation from the side tree. Nodes added from the node palette will have the default rotation.
Figure
...
7. Node rotation
Anchor | ||||
---|---|---|---|---|
|
...
Deactivated nodes are indicated by a grey circle backlash symbol on top of the node icon. Deactivated links become a solid grey line. Figure 9 8 shows what happens when the storage alone was deactivated using Deactivate (left pane), or the storage and all upstream components were deactivated using Multi-deactivate » This and all upstream, or the storage and all downstream components were deactivated using Multi-deactivate » This and all downstream including tributaries (right pane).
Figure
...
8. Deactivation of nodes and links comparison
Note the following about deactivation:
- Multi-deactivate and multi-activate does not work if traversing the network leads back to the starting component, such as an anabranch. Source will notify you if this occurs. For example, it is not possible to use multi-deactivate (either upstream or downstream) on either the environmental demand node or the water user node in Figure 98.
- Two Warning notifications are generated by Source when running a model with deactivated components:
- One indicates how many components were deactivated
- The other indicates how many components were excluded from the run order. Excluding components from the run order will reduce run time.
- Deactivation has not been implemented for a wetland cluster. If a component of a wetland cluster is deactivated, there will be a run time error.
- If a splitter is deactivated, all the flow, constituent and orders are passed down the non-effluent link.
- If a supply point is deactivated, the connected water user will not receive water.