Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Scenario input sets allow you to easily keep model structure, while switching between groups of input data and parameters. These may be used to represent changeable physical attributes, such as climate, land use decisions or even proposed infrastructure characteristics. You can switch between different scenario input sets to compare the effects on a model. For example, you can have one scenario input set consisting of rainfall, inflow and evapotranspiration data for natural conditions, another for wet conditions and a third set for dry conditions.

...

Nodes.Wheat Fields.Inactive Demand Models.Irrigator #0.Crops.Wheat Crop.Planting Decision.Plant Date.Use Expression=False
Nodes.Wheat Fields.Inactive Demand Models.Irrigator #0.Crops.Wheat Crop.Planting Decision.Plant Date.Day=20
Nodes.Wheat Fields.Inactive Demand Models.Irrigator #0.Crops.Wheat Crop.Planting Decision.Plant Date.Month=12

You can also use scenario input sets to change the active demand model at a water user node, for example:

Nodes.Water User 3.Demand Model=MyInactiveDemandModel

If you wish to change some parameters in an inactive demand model, and also make it the active model, then you need to specify the parameter changes first. An example is shown in Figure 2 for the inactive demand model Irrigator #0. 

...


Setting a property in Scenario Input Sets

A function/value can be set in input sets with multiple lines. This is mostly useful if scenario input sets is used to merge changes from multiple users. For example, in a function one might want multiple lines with comments. The syntax looks like:

Functions.Functions.$f_rain.Expression = {MultiLineValue} 
// This is a comment in my function
IF($Now.Day = 30,
200,
0)
{/MultiLineValue}

Similarly, it can be the same syntax for: 

Nodes.Storage 1.Outlet Paths.Link #1.Outlets.Default Spillway.Minimum Discharge = {MultiLineValue}
[[0 0]
[100 0]
[101 864000000]]{m ML/d}
{/MultiLineValue}


Anchor
FileBasedEntry
FileBasedEntry
File-based parameter specification

...

The built-in variable $ActiveInputSet allows you to use the active scenario input set as a variable in a function, for example if($ActiveInputSet = "Wet"1510). The active scenario input set is selected through the Configure dialog (Figure 1). When working with a scenario that contains parent and children scenario input sets (eg, Figure 6), the following conventions apply:

  • To identify a specific scenario input set, use its full path, eg. "Parent1.Child1", or "Parent2", or "Parent2.Child1.Grandchild.GreatGrandchild".
  • To identify any children of a specific scenario input set, use its full path followed by a full stop, eg. "Parent1.Child1." will be true for Parent1.Child1.Grandchild1 and Parent1.Child1.Grandchild2.
  • To identify a child scenario input set, regardless of its parents, use its name preceded by a full stop. For example ".Child1" will be true for Parent1.Child1 and Parent2.Child1
  • The previous two conventions can be combined to identify any children of a child input set, regardless of its parents. For example, ".Grandchild1." will be true for Parent2.Child1.Grandchild1.GreatGrandchild.
  • If you want to identify a specific scenario input set and any of its children, use an or function combined with an if function. For example if($ActiveInputSet=".Grandchild1" or $ActiveInputSet = ".Grandchild1."51) will be true for  Parent1.Child1.Grandchild1, Parent2.Child1.Grandchild1 and Parent2.Child1.Grandchild1.GreatGrandchild.

...