Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

You can change between the Backward Euler reservoir routing methods (default) and the Piecewise-linear Integral in Scenario Options » Storages.

...

  • Resource assessment and water allocation
  • Ownership
    • of storage volume, inputs, losses, spills and outlet capacities
    • Internal spilling between owners
    • Internal ceding (transfer from one owner to another based on agreed protocols)
    • Local borrow and payback systems.
  • Weir operation (where the routing of flows in the headwater is significant - ie long flat weir pools)
  • Ordering
    • Storages in series (orders passed upstream and transfer between storages),
    • Storages in parallel (choice of supply storage, optimisation of order delivery).
  • Water quality in storages.

...

Table 1. Example of pre-computed solution table

Image Modified


These values stay the same for the length of the model run and can then be used at each time step. Using the current value of Ordersj and Edepth we can calculate the corresponding value of ε for each table row (V):

...