You can change between the Backward Euler reservoir routing methods (default) and the Piecewise-linear Integral in Scenario Options » Storages.
...
Where Out consists of a number of components:
- Nett Net Evaporation
- Seepage
- Release
- Spill
...
Table 1. Example of pre-computed solution table
These values stay the same for the length of the model run and can then be used at each time step. Using the current value of Ordersj and Edepth we can calculate the corresponding value of ε for each table row (V):
...