Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Generic Treatment Node Properties Dialogue Box


Image RemovedImage Added

Inlet Properties

...

For flow, performance of the Generic Treatment can be described using flow based capture efficiency as shown below:

 Image RemovedImage Added


For each pollutant (TSS, TN, TP and gross pollutants), performance of the Generic Treatment can be described using one of three options as shown below:

  1. A concentration-based capture efficiency (defined by a table) - define the outlet concentration as a function of the inlet concentration;
  2. A flow-based capture efficiency (defined by a table) - Entered in a table, this allows you to define a percentage of capture of each pollutant as a function of the flow. A 100% capture represents a total reduction of the pollutants, whereas 0% capture means that the node has no effect on the pollutant. Note that if your table does not cover the entire hydrograph then music extrapolates linearly using the last two values of the table; or
  3. A combination of the above options  - When the option Both is selected, the concentration-based transfer function is applied on the captured percentage of the flow. This provides greater flexibility and more options in your model. For example, you can model reduced efficiency with higher inflows into the GPT. The concentration-based reduction can now be altered by the flow-based efficiency, thus providing higher accuracy.


The Properties dialog shown above is used in the example described next.

This table shown below has been extracted from the recorded file. Notice the following:

  • At 19:54, the inflow is 0.237 m3/s, so the flow based capture efficiency will be 100%. Then, the concentration based transfer function will apply to 100% of the incoming flow, i.e. 234 mg/L • 0.4 = 93.5 mg/L.

  • At 20:00, the inflow is 1.63 m3/s, so the capture percentage is 50% (as defined in the table of the previous figure). Then, the concentration based transfer function will apply to the captured flow (i.e. 50% here).

  • 50% of the flow with 50.2 mg/L reduced to 50.2•0.4 = 20 mg/L and 50% of the flow not captured, at 50.2 mg/L gives the final value of 0.5•20+0.5•50.2 = 35.1mg/L.



Time

Inflow (m3/s)

Totaloutflow (m3/s)

TSSinflow(mg/l)

TSSoutflow(mg/l)

TSStotaloutflow(mg/l)

25/04/1970 19:54

0.237

0.237

234

93.5

93.5

25/04/1970 20:00  

1.63

1.63

50.2

35.1

35.1


To use the function editor:

  • Select the required pollutant using the radio-buttons adjacent to each pollutant. For each pollutant, you can choose how to display the transfer functions: as a concentration based transfer function only, as a flow-based capture efficiency only, or both. This is done using the appropriate radio buttons above the Transfer Function Tables.
  • You can add new points in the table manually. You can also import the file.


If you wanted to simulate a Generic Treatment which removed 90% of all gross pollutants, you would create a straight line with a slope (ie. output/input) of 0.1, as expressed by the form:

  • Gross Pollutant Output = 0.1 • Gross Pollutant Input.


Using the above example, this would be created by entering an output value of 100 for an input value of 1000.


...