Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

When the stormwater inflow rate exceeds the user-defined High Flow Bypass amount (in units of m3/s), only a flow rate equal to the High Flow Bypass (less that specified in any Low Flow Bypass) will enter and be treated by the infiltration system. All of the stormwater flow in excess of the High Flow Bypass amount will bypass the infiltration system and will not be treated.


Info
iconfalse

Image Modified Tip Box

The Low and High Flow Bypasses are assumed to occur simultaneously. So for a Low Flow Bypass of 2m3/s, a High Flow Bypass of 8m3/s, and inflow of 10m3/s:

...

Image Modified


Storage Properties

The StorageĀ  Properties define the physical characteristics of the surface storage above the infiltration medium the infiltration system.

...