Introduction
Gross pollutants form a significant part of the total amount of pollutants deposited in urban catchments in Australia. Allison et al. (1998) estimated that the total wet mass of gross pollutants deposited within Melbourne amounts to 60,000 tonnes annually. As well as reducing aesthetic values in the catchment, these pollutants play a significant role in disturbing physical habitats and degrading water quality within the waterway.
...
As can be seen from Figure 1, the relationship derived from the data by Allison et al. (1998) indicates that events with runoff depths less than approximately 0.7 mm will produce no gross pollutant load. As noted by Walker and Wong (1999), this indicates that events with runoff less than 0.7 mm are not able to mobilise and transport material that has been deposited on the street surface. It is further noted that the shape of the rainfall versus wet load curve suggests that there is a possible upper limit of gross pollutant load that will be transported into the stormwater system. However, as noted by Allison et al. (1998), the data presented in this graph represents sampling collected during a three month period. Although it is recognised that this data is the best available, these relationships can be refined as more data becomes available.
Figure 1. Gross Pollutant Wet Load Generation, after Walker and Wong (1999)
The Gross Pollutant Generation Algorithm Adopted in MUSIC
MUSIC uses the relationship presented in equation 1 to determine the wet mass generated during storm events from the impervious area of a source node only. It has been assumed that no gross pollutants are generated from the pervious area of a source node. In the algorithm adopted, the wet mass per hectare, for each day of the simulation is calculated from the impervious area runoff using equation 1. The total daily wet mass is determined by multiplying this value by the total catchment area. Where equation 1 produces negative values, for events with impervious runoff less than 0.7 mm, the algorithm assumes that the wet mass generated during that day is zero.
The variation in the gross pollutants during each day is calculated by distributing the total wet mass over periods where surface runoff has occurred. The aim of this approach is to attempt to distribute the gross pollutants during the storm event only, and not during baseflow conditions. The wet mass of gross pollutants in each time step during the day is calculated as being proportional to the surface runoff hydrograph. Gross pollutants are routed through the drainage system using the same algorithms adopted for other contaminants. Unlike other contaminants, gross pollutants entering all treatment nodes, except the gross pollutant trap and generic treatment nodes, are assumed to be 100% captured. Stormwater by-passing the treatment nodes will also convey gross pollutant to the downstream node. Gross pollutant and generic treatment nodes allow the user to specify the gross pollutant trapping efficiency to be used.
Treatment of Gross Pollutants and Other Contaminants in Gross Pollutants Traps by MUSIC
MUSIC provides a treatment node for the treatment of stormwater quality using a gross pollutant trap. The treatment node adopted is a variation of that used for the generic treatment node, with the exception that there is no provision for modifying flow rate, as there is with the generic treatment node. The treatment of gross pollutants and other contaminants is modelled in MUSIC using transfer functions. These transfer functions calculate the stormwater effluent concentration from the concentration of the stormwater flowing into the device, using a simple graphical relationship between the inflow and outflow concentration.
...
The results presented by Walker et al. (1999) show that where the inflow concentration of TSS is below 75 mg/L some reduction in the outflow concentration was noted. However, in some cases the concentration of TSS in the outflow was larger than that entering the device. It was noted that in some cases where the concentration of the influent fell below the ‘background’ concentration of 75 mg/L, there was little or no treatment by the device. Where the influent concentration of TSS exceeded this ‘background’ concentration, there was significant treatment of TSS taking place within the device. At these higher inflow concentrations the device had a treatment efficiency of 70 % of the concentration above 75 mg/L. The graphical representation of this treatment efficiency for TSS is shown in Figure 2. It was also concluded from the tests undertaken that the CDS device did not affect TSS concentrations during dry weather flow conditions.
Figure 2. Inflow and Outflow TSS Concentrations from a CDS Unit, after Walker et al. (1999)
Tests undertaken by Walker et al. (1999) also indicated that where the inflow concentration of TP exceeded 0.5 mg/L there was an apparent removal of TP within the device. For inflow concentrations below 0.5 mg/L there was little or no treatment within the device. The estimated removal efficiency for TP for inflow concentrations above this background concentration was found to be approximately 30% of the concentration above 0.5 mg/L. A graphical representation of the treatment efficiency for the treatment of TP by the CDS device is presented in Figure 3. The results from the CDS device also indicated that the removal of TN within the device was erratic during storm events as shown in Figure 4. However, the results for dry weather flow suggest that there is consistent removal of approximately 13 % of TN during dry weather flow conditions.
Figure 3. Inflow and Outflow TP Concentrations from a CDS Unit, after Walker et al. (1999)
Figure 4. Inflow and Outflow TN Concentrations from a CDS Unit, after Walker et al. (1999)
Conclusions
This appendix provides a brief background on studies that have been undertaken on the generation of gross pollutants in urban catchments. The studies reported are limited in that they relate to limited testing periods undertaken within an urban catchment in Melbourne. The studies reported have also looked at the treatment efficiency of gross pollutant trap devices. It must also be emphasised here that the treatment efficiency results reported in the studies are limited as they relate to a single gross pollutant trap device type in a single catchment. However, the studies reported provide a good basis for estimating the treatment efficiencies to be gained from gross pollutant traps.
MUSIC provides a generic treatment methodology for predicting the treatment effects that will occur within a gross pollutant trap. This provides the user with a flexible tool that can be modified to represent the current best estimates of treatment efficiency, as reported in the studies described in this appendix. One of the benefits of the treatment methodology adopted within MUSIC is that it allows for the incorporation of new research as it becomes available on the treatment efficiencies of different devices, under different maintenance routines and in different climatic zones.
References
Allison, R. A., Walker, T. A., Chiew, F. H. S., O'Neill, I. C. and McMahon, T. A., 1998, "From Roads to Rivers - Gross Pollutant Removal from Urban Waterways", Report 98/6, CRC for Catchment Hydrology, May.
...