In regulated river systems, storages control the supply of water to consumptive and non-consumptive users, and may also provide flood mitigation, social and environmental services. In a river model, they represent places where water is stored along the river, such as dams, reservoirs, weirs and ponds. Storages operate by maintaining water mass balance. 

...

In Source, the storage node operates by calculating the minimum and maximum discharge based on current inflows and user defined discharge, gain and loss relationships. They maintain water balance and assume that the change in storage height across a time-step is small compared to the storage fluxes. Additionally, it assumes that any flows fluxes into or out of the storage are distributed throughout the time-step. Flows and changes in storage volume are calculated by integrating across the time-step.  

For all storages

...

in Source, four aspects must be configured as a minimum in the node’s feature editor:  

  • Details of the storage such as its dimensions and capacity;
  • Inflows to storages such as stream flow from upstream catchments, rainfall over the storage surface area,

...

  •  recharge from groundwater, and runoff from the catchment surrounding the storage;  
  • Outflows from the dam, which could be initiated either through controlled releases (to fulfill downstream demand) or uncontrolled flows; and
  • Losses that constitute evaporation from the storage surface area and seepage to groundwater.  

The editor’s main window (

...

Figure 1) allows you to specify storage details

...

, which are outlined in Table

...

1.

...

 You are recommended to use the same units as those in Dimensions, but you can change them by clicking on their respective units buttons.

Figure 1. Storage node

Image Added

Table 1. Storage node, details
ParameterDefinitionDefault
Full Supply

The level or volume for which uncontrolled flow commences over an un-gated spillway.

Equal to the level of the spillway.
Initial Storage

The initial water level/volume in the storage at the start. This level must be above or equal to the minimum storage water level defined in the storage dimensions relationship.

There is no default value, but it can be a non-integer, with the minimum being the lowest storage dimension level.
Dead StorageThe level or volume below which water cannot be released from the storage. This is different for rules-based and netLP ordering. Refer to the note below.0
Info
iconfalse
Note: In rules-based ordering, the defined dead storage does not impact on the ability to release; this is only affected by the storage’s outlet characteristics. In netLP ordering, the defined dead storage level overrides the storage outlet characteristics, that is, an outlet cannot release water below the defined dead storage level, even if it is configured to be able to release below the defined dead storage level.

Releases from storages are normally assumed to be constant through the time-step (limited by volume to the minimum

...

or maximum release curves). Enabling the

...

Adaptive Storage Release Method check box generates a release curve based on the orders combined with the outlet curve. With this option, the storage would release at maximum release rate where the storage couldn’t release at ordered rate. The storage would release at minimum release rate when it was greater than the order. The adaptive storage release method will generate small artifacts when switching between the order and maximum/minimum release rates. However, it should provide better handling of releases when there are multiple outlets with big operating ranges.

...

The maximum operating target refers to the full supply level where a maximum target level/volume has been defined based on an operating and management decision, such as to maintain airspace for flood mitigation. Note that you can only specify either the level or volume, although only the level is retained.

Storage node (Main window)

Image Removed

Storage dimensions

...

 

Both Minimum operating level and Maximum operating level are only used when the storage is configured as a weir. Outlets MUST be configured correctly, and an ungated spillway must NOT be configured as the default outlet. The storage will not release water to satisfy downstream requirements if this results in the water level dropping below the minimum operating level. Likewise, water will be released to prevent the storage rising above the maximum operating level.

Note

Outlet configuration can override the minimum and maximum operating levels.

Operating target is the level that the system will attempt to maintain in a downstream storage by transferring water from an upstream storage.

Storage dimensions

Select Dimensions (Figure 2) to specify the dimensions of the storage node using level, volume and surface area. It can be entered manually as a piecewise linear relationship or imported as a comma-separated file (format shown in Table 1). The graph displays a relationship between

...

Level vs Volume or Level vs Surface Area, which can be changed using the drop down menu. You can also export the relationship for use in another scenario.

Figure 2. Storage node

...

, Dimensions

...

Image Modified

...

Table 2. Storage node, Dimensions (

...

data file format) 
RowColumn (comma-separated)
123
1Level (m)Volume (ML)Surface Area (ha)
2000
3

...

levelvolume

...

surface area

...

surface area

...

Constituents

These inputs are required for water quality constituents, and can be specified by

...

Storage node (Constituents)

Image Removed

Storage node (Constituents, Inlet Channel Mixing)

Image Removed

Gauged Level

...

selecting Constituents. Ensure that constituents have been defined prior to configuration (using Edit » Constituents). The dialog for configuring constituents is the same as for links. Hence, refer to Links for details.

Gauged Level

The Apply Unaccounted Difference to Storage level calculation check box allows you to enable modelled values to be overridden by observed values.

...

The storage level

...

forces the parameter to equal the observed value. You can link the source data to a

...

time series, an expression

...

, or the output of another scenario, as shown in

...

Figure 3.

 Figure 3. Storage node

...

, Gauged

...

level

Image Modified

Gauged Releases

This

...

item shows a list of storage releases that are forced to be equal to observed releases

...

. Click on the disclosure triangle to view these. Then, right click to enable the required release. For each outlet path, you can source observed release from either

...

a time series, an expression

...

, or

...

the output of another scenario, as shown in

...

Note that the default value is no forecast release model. If you configure a forecast model, releases in the forecast period can be forecast using the same method as for the Inflow node.

...

Figure 4.

Figure 4. Storage node, Gauged releases 

Image Modified

Outlets

Outlets (

...

Figure 5) define how water is released from the storage and must be added to allow for spills. In Source, you must specify the following: 

  • Outlet path

...

  • the path (out of the storage node) taken by the outlet. To choose an outlet path,

...

  • click on the disclosure triangle to open a list of links connected to the node. You can choose the link that is associated with an outlet by right-clicking and choosing the outlet type;
  • Outlet types

...

  • right-click on Outlets and choose the outlet type from the contextual menu.You can add more than one outlet type per storage. These are shown in Table

...

  • 3. Storage Outlet Types; and  
    You can enter a relationship between storage level and discharge for each outlet as a piecewise linear relationship (format shown in Table

...

  • 4.).You can also see a piecewise linear relationship accounting for all the release types (eg if you have a gated spillway and a culvert) in the table for Total

...

  • Outlet

...

  • Capacity.
Table 3. Storage Outlet Types
Outlet TypeDescriptionPiecewise linear function required
Culvert

A conduit is used to enclose a flowing body of water. It may be used to allow water to pass underneath a road, railway or embankment.

Level vs discharge
Gated Spillway

Controls releases by the operation of gates. This allows for arange of discharges rates for each water level, depending on how wide the gates are opened.

Level vs minimum and maximum discharge

Hydropower ValveThe power generated from a hydroelectric system.

Level vs maximum discharge

Pump

Used to extract water from the storage (rather than allow discharge). This may be used where the location of the demand is at a higher elevation compared with the storage, or to extract water from the dead storage and which is below other release structures

Level vs maximum water pumped
Un-gated Spillway

A structure that controls the spill of water from a storage. It is designed to spill water once the storage is full and ensures that any spills are controlled. This prevents the storage from failing. Un-gated spillway rating tables are used to populate the Discharge table. The full storage level should have a zero discharge and the discharge depth needs to be calculated as the height above the full storage level.

Level vs discharge

Valve

Used to release water via a pipe. Valves normally release environmental flows from storages. The valve rating table is used to control the volume of water released via this method.

Level vs maximum discharge

Table 4. Storage node, Seepage (data file format)
RowColumn (comma-separated)
 12
1Level (m)Seepage (mm/d)
200
3levelseepage

 

Note that when there are multiple outlets configured, water will flow down the outlet path assigned to the default spillway. Also, when a minimum flow requirement node is connected downstream of the storage node, water will flow through the path that links it to the storage.

Figure 5. Storage node

...

, Outlets 

Image Modified

Rainfall

Rain falling directly over the storage reservoir can be input as a time series

...

, using the expression editor (such as adding a daily or monthly pattern), or linking to the output of another scenario, as shown in

...

Figure 6. It is assumed to occur only on the surface area. Daily rainfall data near the storage is required and can be obtained from managing agencies, SILO or the Bureau of Meteorology. 

Figure 6. Storage node

...

, Rainfall

...

Image Modified

Evaporation

Evaporation directly from the storage surface can be input as a time series

...

, an expression

...

, or linking to the output of another scenario (

...

Figure 7).

Figure 7. Storage node, Evaporation

Image Modified

Seepage

Water can infiltrate into the ground where the soil is not fully saturated. Where groundwater intercepts the surface, water can seep from groundwater into the storage, where infiltration can occur wherever there is a ground/water interface. Seepage (

...

Figure 8) is specified using a piecewise linear relationship between storage level and infiltration volume/time. Note that you cannot specify negative values

...

. The data file format for seepage is shown in Table

...

4.

Figure 8. Storage node

...

, Seepage

...

Image Modified

Anchor
Weirs
Weirs
Weirs 

You can specify whether this storage will operate as a weir by right-

...

clicking Storage and selecting Convert to Weir to enable Upstream

...

Reach (

...

Figure 9). This feature can only be defined if the storage is configured as a weir. The upstream reach represents the storage relationship in the stretch of

...

river that the weir inundates. You can define the storage in the same manner as a link

...

, which may be important for constituent modelling. If you do not want to configure storage routing through a weir, you can define the upstream storage relationship as 0. Refer to Links for configuring groundwater, loss/gain etc.

The weir-related data entered for the storage node refers to the volume of the upstream reach that

...

is inundated for a given operating level of the weir. The outlet relationships of the weir allow you to define a default outlet, which represents the main downstream flow path from the weir. For a re-regulating weir, this should be a Gated Spillway. Ensure that you incorporate the rating curve further downstream of the default outlet to constrain the maximum outlet capacity of the Gated Spillway.

Figure 9. Storage node

...

, Upstream

...

reach

Image Modified

...

Forecasting in storages

...

  • Evaporation forecasting
  • Rainfall forecasting
  • Release forecasting

Refer to Forecasting for more details.

Ordering

...

storages

If your model uses optimised ordering, you should leave the priority level of each link at its default value of 1. Refer to Figure 10 for details on configuring ordering for the storage node.

Figure 10. Storage Node, Ordering

Image Added

Ownership in storages

...

In ownership, observed values may not be available for every time-step. Additionally, observed values cannot include negative numbers, as ownership of storages can potentially result in negative shares when you support borrow and payback.

...

Storage node (Storage details)

Parameter

Definition

Default

Full Supply

The level or volume for which uncontrolled flow commences over an un-gated spillway.

Equal to the level of the spillway.

Initial Storage

The initial water level/volume in the storage at the start. This level must be above or equal to the minimum storage water level defined in the storage dimensions relationship.

There is no default value, but it can be a non-integer, with the minimum being the lowest storage dimension level

 

Storage outlet types

Outlet Type

Description

Piecewise linear function required

Culvert

A conduit is used to enclose a flowing body of water. It may be used to allow water to pass underneath a road, railway or embankment.

Level vs discharge

Gated Spillway

Controls releases by the operation of gates. This allows for a range of discharges rates for each water level, depending on how wide the gates are opened.

Level vs minimum and maximum discharge

Hydropower Valve

The power generated from a hydropower.

Level vs maximum discharge

Pump

Used to extract water from the storage (rather than allow discharge). This may be used where the location of the demand is at a higher elevation compared with the storage, or to extract water from the dead storage and which is below other release structures

Level vs maximum water pumped

Un-gated spillway

A structure that controls the spill of water from a storage. It is designed to spill water once the storage is full and ensures that any spills are controlled. This prevents the storage from failing. Un-gated spillway rating tables are used to populate the Discharge table. The full storage level should have a zero discharge and the discharge depth needs to be calculated as the height above the full storage level.

Level vs discharge

 

Storage node (Outlets, data file format)

Row

Column (comma-separated)

1

2

1

Level (m)

Discharge (ML/d)

2

0

0

Where: level is the storage level measured in metres
discharge is the associated discharge measured in megalitres per day

Storage node (Seepage, data file format)

Row

Column (comma-separated)

1

2

1

Level (m)

Seepage (mm/d)

2

0

0

...

Refer to Figure11 for details.

   Figure 11. Storage node (Ownership)

Image Added