Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Principal Developer

eWater Solutions

Authors

Rachel Blakers, Andrew Davidson

Version

Source v4.1

Availability/Conditions

The Exponential Decay model is automatically installed with Source. For Lumped constituent routing, it can be applied to constituents in:

...

Anchor
_Ref451270116
_Ref451270116
Equation 2

Image RemovedImage Added

where M0 is the initial quantity.

...

where Mt is the constituent mass at the end of time step t, Vt is the storage volume at the end of time step t, and is the time step size. Equation 7 assumes that flux rates are constant during a time step and that the storage volume at the end of the time step is representative of the volume during the time step. It is more convenient to express the change in constituent mass with respect to the half-life h. An expression for the half-life can be derived for Equation 7 as:

Equation 8

Image RemovedImage Added

Using the above expression, we can then express Equation 7 in terms of the half-life rather than the decay constant:

Anchor
_Ref451254496
_Ref451254496
Equation 9

Image RemovedImage Added

Equation 9 forms the basis of the Exponential Decay model in Source. The solution becomes less accurate as the half-life becomes smaller (particularly if the half-life is smaller than the time step) and as the flushing rate (Qout /Vt+1) becomes larger. It also follows from Equation 9 that if Vt+1 = 0 then Mt+1 = 0.

Trend Concentration and Percent Reduction%

This function allows to decay concentration and then remove the certain percentage of the constituent. The basic formula is the equation 9.

Trend Concentration 

It considers two conditions:

(i): Trend Concentration < Concentration at the begging of time step:

Image Added

Where:

M'(t+1) is the constituent mass after the process of Trend Concentration 

A= V* TrendConcentration is the total mass for the task concentration.


(ii): Trend Concentration > Concentration at the begging of time step

Image Added




Percent Reduction%

The function will remove the input percent value directly from the processed constituent mass.

Image Added

Where:

C’(t+1) is the constituent concentration at the storage after the process of Trend Concentration

M’’(t+1) is the sum of the constituent mass after the process of Trend Concentration and in the outflow

M(t+1) is the final constituent mass after the process of Trend Concentration and Percent Reduction.

Example

If the half-life is equal to the time step, then the constituent mass after one time step will be equal to one half of the previous mass (ignoring losses and gains from outflows and inflows). For example, consider a half-life of = 1 day, a daily time step, zero inflows and zero outflows. Equation 9 tells us that, after 1 day, the constituent mass will be:

...

Parameter

Description

Units

Default

Range

Half-life

The half-life of the constituent

seconds

86400 (equivalent to 1 day)

0 to ∞

Percent Reduction

A percent value that the user wishes to remove directly from the processed constituent

%00 to 100
Trend Concentration 

The concentration to trend down to

mg/L00 to ∞

Outputs

A time series of stored constituent mass.

...