To enter a user defined timer series, either type in the file path and file name, or click on the Browse button, to locate a previously prepared comma separated value (CSV) file which contains the reuse rate (in L volume per time-step). The re-use file must be a CSV file with a separate reuse value on each line. The time-step for the reuse file must be the same as that used in the meteorology template file. Only a single column of data should be provided in the CSV file. A header row may also needs to be incorporated or may be left blank.
Demand will only be met when there is available storage in the permanent pool of the treatment node.
...
As discussed above, a user defined time series of reuse can be specified in music using Custom Demand Tab and importing data. This facility provides a more realistic reuse demand specification capability. The facility also allows exploration of the impacts of reuse that could not previously be simulated, such as trends in household demand, steps in demand as occupancy changes, etc.The time-step for the reuse file must be the same as that used in the meteorology template file. A single header row should be incorporated.