Pipe junction functionality is provided in Source to allow modelling of bidirectional flows between storage.
Scale
Model operates at the site scale and at any time step Source is capable of using (e.g. daily).
Principal developer
eWater Solution
Version
Source version 4.5
Dependencies
At least two Pipe Junctions are required in the network to define connections.
Availability
Automatically installed with Source.
Input data
Refer to the Source User Guide for detailed data requirements and formats.
Output data
Outputs include the following results:
- Actual Flux: actual flow that has been pumped
- Actual Flux Volume: actual flow volume that has been pumped
- Expected Flux: expected flow that plan to pump
- Expected Flux Volume: expected flow volume that plan to pump
- Difference between expected and actual flux
- Difference between expected and actual flux volume
- Capacity: predicted pump capacity
- Cost: pump cost per ML, only available with NetLP
- Flow Volume: Actual pumped volume