Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 26 Next »

A time-series demand model allows you to extract water directly from a storage and identify the amount of water required to satisfy a demand at each time-step. The model does not have to be directly downstream of the storage, the supply point will order water from the storage to meet demands.

If a confluence node is connected between a storage node and a water user demand node, the flow pathway link in the confluence must be set to Regulated for the storage to order water to satisfy the demand downstream. If it is left unregulated, water will not be ordered from the storage and the supply point will pull water from the river at the point in the network that it sits to meet the demand. if the demand is higher than the volume in the reach, then the supply point will extract everything.

If there is no storage in the network above the supply point and water user node, then the volume is extracted from the river at the point where the supply point sits in the network.

Figure 1 shows the feature editor for the Time series demand model.

Figure 1. Water user node (Time series demand model)

Time-series demands can be specified using either a single value, a time-series data file (Table 1 shows the format of a file) or an expression using the Function Editor.

Refer to Return flows for details on configuring this parameter.

Table 1. Water User node (Time Series Demand, data file format)

Row

Column (comma-separated)

1

2

Where:

date is the date of observation in dd/mm/yyyy format (eg 31-12-2000)

value is the observed value (eg 2600).

  • No labels