Introduction

The behavioural model provides simulation of water use using the Behavioural End-use Stochastic Simulator (BESS) of Thyer et al. (2011), described further in the Urban Developer Plugin SRG

For indoor water uses, the water use simulations for each household are based on the type of water-using appliance (end-use) and the household occupancy of that household. The difference from the average daily model is that instead of specifying an average daily volume and percentages for each end-use, the user specifies the water-using appliance and household occupancy and BESS simulates the water for each individual end-use using the in-built parameters for the water use event dynamics.

BESS uses a sub-daily diurnal pattern based on Roberts et al. (2005) to vary the probability of water use events occurring throughout the day. 

For outdoor water use, the behavioural model uses a time series or monthly varying pattern of average daily values, which can be input by the user - similar to the average daily model. For sub-daily outdoor water use, daily values are evenly distributed throughout the day. 

The Behavioural Water Use node allows the user to specify a unique combination of end-uses which will be applied to one or more houses. In this way the node becomes a template representing a specific urban demand configuration. For example, a single node can be configured to represent all Detached homes with a Pool.

Contents

Node Dependencies

The Behavioural Water Use node requires that the following inputs are configured through the Urban Developer Options:

The allocation and application of these parameters is further described in the Urban Settings section in the Urban Developer Plugin User Guide and the  Behavioural Model Configuration section in the Urban Developer Plugin SRG.

Restrictions

There are restrictions on which node inputs and outputs you can connect together. See Urban Developer node connection rules.

The Behavioural Water Use node is available for Urban Scenarios only.

Node Properties

Node PropertyNotes
Number of housesSpecify the number of houses the node represents 
Occupants per houseSpecify the number of occupants per household (applies only when the behavioural model configuration is set to Appliances. When the behavioural model configuration is set to Sampled appliances and occupancy, these properties are grayed out in the user interface. Refer to section 2. Urban Settings for details.)
Average appliance demand

Switches between Average and Stochastic demand generation


End-use appliance type

Indoor end-use includes showers, taps and dishwashers, toilet and dishwashers as appliance types. Specifications for indoor water use appliance types are set under the Urban Developer Options described in section 2. Urban Settings.

Pool is currently the only end-use available under Outdoor end-use

Outdoor average daily demandThis typically represents a seasonal variation in water use. The average daily demand can be specified using a single value, a time series, a function or a monthly pattern. By default a monthly pattern is applied.
Supply source priorities

For each indoor/outdoor end-use, specify which supply sources are available an order of preference.

For example, for the end-use Toilet (illustrated in Figure 1):

  • In the Rainwater Tank row, check Use and enter 1 in the Priority column to specify that rainwater is the first preference for toilet flushing
  • In the Mains row, check Use and enter 2 in the Priority column to specify that, if no rainwater is available, then use Mains water as the second preference for flushing.

Un-checking Use for a supply source specifies that it will not supply that particular end-use.

Discharge breakdown

For each indoor/outdoor end-use, specify the percentage of water discharged as blackwater, greywater, or Irrigation/other wastewater.

The values will be re-scaled so that they sum to 100%.

User Interface

The Behavioural Water Use node is configured via the node Feature Editor, illustrated below in Figure 1. to Figure 4. The first window of the Behavioural Water Use node (Figure 1) allows the user to set the Number of houses which will use the end-use configuration specified on this node. This will be 1 if applying the node as a template for an Urban Combination Configuration run. Water end-use is categorised as Indoor and Outdoor use. 

Figure 1. Behavioural Water Use node editor


Four end-use options are available for Indoor water demand allocation. 

Figure 2. Configuring end-use options in the Behavioural Water Use node editor

Average Appliance Demand

The average appliance demand is an option that can be used in conjunction with sampled or fixed appliances and occupancy.

Average values for usage frequency and water consumption are used, rather than simulating the water consumption for individual appliance usage events by sampling from the probability distributions set up under the Urban Developer Options described in section 2. Urban Settings. The average values are configured in the Appliance Types menu.

The average appliance demand model is enabled using the Use Average Demand check box in the Behavioural Water Use node Feature Editor.



References

Roberts, P. (2005) 2004 Residential End Use Measurement Study, Final Report: Yarra Valley Water, Victoria.

Thyer, M., Micevski, T., Kuczera, G., and Coombes, P. (2011) A Behavioural Approach to Stochastic End Use Modelling. Paper presented at Oz Water, 9-11 May 2011, Adelaide.

Acknowledgements

This material has been adapted from:

eWater Cooperative Research Centre (2011) Urban Developer User Guide: Urban Developer v1.0.0, eWater Cooperative Research Centre, Canberra, 29 June 2011. ISBN 978-1-921543-40-1