The Export Rate model applies a fixed constituent generation rate to a functional unit (FU) to calculate total constituent load. It requires only a single parameter so is quick to use and therefore useful for exploring sensitivity.

Scale

This model is applied at the functional unit scale within a sub-catchment.

The model is a scaling factor and is independent of the basic time-step of the model. It is therefore more appropriate for estimating long term loads.

Principal developer

Cooperative Research Centre for Catchment Hydrology.

Version

Source v2.10

Availability/conditions

Export Rate is automatically installed with Source.

Flow phase

The Export Rate model is a simple area-based scaling factor for constituents from a functional unit. It defines a value between 0 and ∞, representing the physical amount of constituent exported per unit area per year.

For constituent C

Input data

A single value representing the export rate in units of tonne/ha/year is required. Area of the FU is taken from the model.

For export rates:

Parameters or settings

The parameters for this model are summarised in Table 72.

Output data

Constituent load in kg per time-step.

References

Fletcher, T, Duncan, H, Poelsma, P & Lloyd, L 2004, Stormwater flow and quality, and the effectiveness of non-proprietary stormwater treatment measures - a review & gap analysis, Technical Report 04/8, Cooperative Research Centre for Catchment Hydrology.

Table 72. Model parameters

Parameter

Description

Units

Default Min

Default Max