Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 9 Current »

Buffer strips are commonly used as a source control measure, particularly for management of diffuse runoff. Buffer strips are vegetated strips adjacent to drainage lines, rather than constructed vegetated channels, which are known as swales. Buffer strips are effective in the removal of coarse to medium sized suspended solids and bed loads and can be used as a pre-treatment to linear infiltration systems such as bio-retention systems. They also can assist in reduction of peak flows for smaller events and may promote infiltration dependent upon the underlying soil conditions. Buffer strip treatment only applies to runoff from impervious surfaces and can be used to represent catchment conditions where runoff from impervious surfaces needs to flow across grassed areas towards the stormwater drainage system.


Tip Box

Buffer Strips must be located directly downstream of a source node and cannot be located downstream of a treatment node.

Buffer Strip Properties

The treatment processes in a buffer strip are modelled by a set of simple transfer functions, derived from a review of worldwide literature (Fletcher, unpublished data):

TSSout = 0.27 + (1.8 x 10-5Hydraulic Load)* x TSSin

TPout = 0.52 + (8 x 10-6Hydraulic Load)* x TPin

TNout = 0.67 + (9.24 x 10-6Hydraulic Load)* x TNin

where concentrations are in mg/L, and Hydraulic Load is in m/year.

*For inflow concentrations below defined concentrations (TSS= 13.7mg/L, TP = 0.143 mg/L, TN = 1.680 mg/L), no treatment occurs.



Percentage of Upstream Area Buffered

This refers to the proportion of the Source Node’s impervious area which has buffer strips applied to it. For example, in a Source Node with 20 ha of impervious area, 2 ha (or 10%) may have buffer strips applied.

Buffer Area

This is a measure of the actual size of buffer strips, defined as the percentage of the Source Node impervious area. The default value is 5%. This means that the total area of buffer strip is equivalent to 5% of the Source Node impervious area.

Exfiltration Rate

Exfiltration from the buffer strip into the underlying soil can be modelled by defining the exfiltration rate (mm/hr). Representative exfiltration rates for different soil types are provided in the table over the page. The water that seeps from the buffer strip is lost from the catchment, and cannot re-enter the system downstream. Contaminants in the water that is lost to exfiltration are removed from the buffer strip, along with the exfiltrated water and are also lost from the catchment. Representative exfiltration rates for different soil types are shown in the following table.


Soil TypeMedian particle size (mm)Saturated Hydraulic Conductivity
(mm/hr)(m/s)
Gravel2360001x10-2
Coarse sand136001x10-3
Sand0.73601x10-4
Sandy loam0.451805x10-5
Sandy clay0.01361x10-5

Tip Box

This simple example may help to explain the specifications for buffer strips. If a Source Node with an impervious area of 100 ha has buffer strips applied to 20 ha, and the buffer strips occupy 5 ha of land:

Percentage of Upstream Impervious Area Buffered = 20%

Buffer Area = 5%


It is possible to  view or save various  inflows, outflows, water quality for the Swale. You need to select them to record before you run. 


Buffer Node can be edited via Feature Table Buffer node display on Feature Table shown below: