Note: This is documentation for version 4.11 of Source. For a different version of Source, select the relevant space by using the Spaces menu in the toolbar above

Assurance Rules

Source has a set of Assurance Rules that provide optional checks of models, accessible via Edit » Scenario Options. Assurance Rules define and detect unacceptable states in the model, increasing the confidence that the user can have in the model and the output data. Users can customize Assurance Rules in Source by choosing the severity of the notification if an Assurance Rule is not met by the model. Further customization is possible by creation of plugins that define custom Assurance Rule(s). Functions with /wiki/spaces/SD49/pages/54362212 may also be used for validation and logging at custom notification levels.

Figure 1. Scenario Options, Assurance Rules

The notification level of each rule can be set using the drop down menu next to each rule. The outcome of each notification level is summarised in Table 1. 

Performance Improvement

Performance can be improved by setting the notification level of an assurance rule to Off, then Source will not check that rule when the model is run. Alternatively, if Enabled is toggled off, all Assurance Rules are set to Off, and are not checked.

Care should be taken when turning off any or all assurance rules. Turning them off is not recommended during model building, but would be useful for calibrating or running replicates. 

Table 1. Assurance Rules, Notification levels
Notification levelSymbolOutcome
Off–The rule is not checked. This will improve performance.
Info

Message logged in the Log Reporter for each instance in which the rule is not met.

Warning

Message logged in the Log Reporter for each instance in which the rule is not met.
Error

Message logged in the Log Reporter for each instance in which the rule is not met.
Fatal

If the rule is not met, the model will stop running.

Assurance Rules and their associated notification levels apply to all model elements in the Scenario. If custom validation and/or differing notification levels are required on a per model basis, then Functions with /wiki/spaces/SD49/pages/54362212 may be used in addition to Assurance Rules.

Each Assurance Rule is described in Table 2.

Table 2. Assurance rule definitions
Assurance Rule CategoryDefinition
Advanced use

All file data sources used in the current input set are checked to ensure they each have a time series assigned to that input set.

Nodes are checked to ensure only confluences have multiple upstream links.

Continuous AccountingAllocation priorities are checked to ensure they match the priorities of the account types.
FunctionsAll functions that are used as an input for a /wiki/spaces/SD49/pages/54362212 (eg. nodes, links) are checked to ensure that the result units configured for the funciton in Function Editor are commensurate with the usage units. For example, a function used as input for an Inflow node, should be set win Function Editor.
Mass BalanceMass balance is checked to ensure it is within the tolerance limit for the entire network and for each catchment, link and node. For example, the rule checks that a node's loss does not exceed inflow. The default tolerance limit is 1 ML, this limit can be changed by navigating to Tools » Application Settings....
Nodes

Storage dimensions are checked to ensure that each level and volume is greater than the previous level and volume. Surface area is checked to ensure that it is greater than or equal to the previous surface area.

Ordering
For constraints, the rule will fail if any constraint exists where:
  • Minimum is infinity; or
  • Minimum is 'NaN' (not a number) eg. divide by 0; or 
  • Maximum has a value and that value is NaN.
     
For orders, the rule will fail if:
  • Any order has a total order volume of infinity; or
  • Any order has a total order volume of NaN; or
  • Any order has an owner that is not part of its upstream ownership system; or
  • Priority ordering is enabled, and:
    • any priority is negative; or
    • any priority is NaN; or
    • the sum of all priorities is not one.

Note, these rules are primarily for debugging purposes, and are set to a notification level of 'None' by default.

OutflowNegative flows are checked for downstream of each node and link.
OwnershipOwnership proportions are checked to ensure they sum to 1
Storage Routing OrderingChecks that the travel time on Storage Routing links is not infinity or negative. This can happen if the representative regulated flow rate for the storage routing link has not been set (in Storage Routing Feature Editor, Avg. Reg Flow = 0 and storage exponent m ≠ 1).